4Quality system requirements#
4.1Hold Points, Witness Points and Milestones#
The quality system requirements defined in MRTS201 General Equipment Requirements apply to this Technical Specification. Additional quality system requirements relevant under this Technical Specification are defined in Table 4.1. There are no Witness Points or Milestones defined.
| Clause | Hold Point | Witness Point | Milestone |
|---|---|---|---|
| 4.2 | 1. Detailed design documentation to be provided prior to manufacture | ||
| 6.3.2 | 2. Mounting requirements | ||
| 6.5.1 | 3. Compliance with MUTCD, TGS and retroreflective material |
4.2Design acceptance#
The requirements of MRTS201 General Equipment Requirements apply to this Technical Specification. Detailed designs of the sign layout, fabrication and assembly drawings, calculations, specifications and certifications of the TCMS components shall be submitted to the Principal for verification, in accordance with the objects of the Professional Engineers Act, prior to manufacture. These components include the TCMS controller, hand-held device, sign face configurations, motor actuator, power supply (including solar power, surge protection and backup batteries), power budget calculations, communication ports, cable termination, enclosure and mounting accessories. Hold Point 1
4.3Warranty#
For TCMS supplied to Transport and Main Roads, the warranty requirements in MRTS201 General Equipment Requirements apply.