4Quality system requirements#
4.1Hold Points, Witness Points and Milestones#
The quality system requirements defined in MRTS50 Specific Quality System Requirements and MRTS201 General Equipment Requirements apply to this Technical Specification. Additional quality system requirements relevant to this Technical Specification are defined in Table 4.1 below. There are no Milestones defined.
| Clause | Hold Point | Witness Point | Milestone |
|---|---|---|---|
| 4.1 | 1. Detailed design documentation to be provided prior to manufacture 2. Optical performance test results to be provided prior to manufacture | ||
| 7.2.4 | 3. Detailed design documentation of mounting structure and footings location and reduced levels (RLs) | ||
| 13.2 | 1. FAT |
Detailed designs of the sign layout, fabrication and assembly drawings, calculations, specifications and certifications of the eTCS components (signed by the Contractor's RPEQ) shall be submitted to the Principal via the Administrator for verification prior to manufacture. These components include, but are not limited to the sign controller, sign face, LEDs, LED matrix boards, pixel arrangements showing horizontal and vertical pitch and total number of pixels, power supply (including surge protection and back-up batteries), communication ports, cable termination, enclosure, and mounting accessories.
Optical performance test methodology and National Association of Testing Authorities (NATA) certification confirming the sign performance requirements specified in this Technical Specification shall be submitted before manufacture. Hold Point 2
4.2Sample eTCS#
A sample eTCS shall be provided for the Site Acceptance Tests (SAT) in accordance with MRTS201 General Equipment Requirements. Where provided, the sample eTCS shall be complete with display and control units of the type to be used in the eTCS to be provided under the Contract.
4.3Warranty#
The Contractor installing the eTCS shall warrant the installation against defects for a minimum of five years in accordance with requirements of MRTS201 General Equipment Requirements.