The following information is to be maintained.
Rate 3 – Road lighting#
Inventory on electrical switchboards#
| Region: |
| Switchboard ID: |
| Description: |
| Road No.: | LGA No.: | Job No.: |
| Road name: | Suburb: |
| Latitude: | Longitude: |
| Plan No.: | Plan rev.: | Rev. date: |
Inventory#
| Item | Value |
|---|
| Switchboard type: | ❑ Main ❑ Submain | Main switchboard ID: |
| Size of consumer mains (mm²): | ❑ 10 ❑ 16 ❑ 20 ❑ 25 ❑ 35 | |
| Type of consumer mains table: | ❑ V75 ❑ V90 ❑ XLPE | |
| Distance from LV terminals / source (m): | ❑ within 10 m ❑ within 100 m ❑ within 500 m ❑ within 50 m ❑ within 200 m ❑ greater than 500 m | |
| Main switch type: | ❑ Fuse ❑ Isolator ❑ MCB | Size: ❑ 63A ❑ 80A |
| No. of circuits: | | |
| No. of spaces for additional circuits: | | |
| No. of phases: | ❑ Single phase ❑ 2 phase ❑ 3 phase | |
| Photocell type: | ❑ NEMA ❑ Other | |
| Photocell location: | ❑ 4.1 m post ❑ Power pole ❑ Other | |
| Housing / cabinet type: | ❑ Pillar box ❑ Ground cabinet ❑ Pole cabinet | |
| Type of earth: | ❑ Common earth ❑ MEN | |
| Location of MEN point: | ❑ Switchboard ❑ Distribution board | |
| Type of earth electrode: | ❑ Pole footing ❑ Earth stake | Size: ❑ 12 mm ❑ 16 mm |
Rate 3 – Road lighting#
Inventory on electrical switchboards#
Current status with respect to the last audit / inspection:#
- Last audit / inspection outcomes not yet reviewed to determine remedial works
- No work required from last audit / inspection
- Decommissioned
- Design phase
- Tender phase
- Construction phase
- Remedial works certified and completed
Inspector name:#
Inspector signature:#
Inspection date:#
Rate 3 – Road lighting#
Inventory on circuits and cables#
| Field | Value |
|---|
| Region: | |
| Switchboard ID: | |
| Description: | |
| Circuit ID: | |
| Description: | |
| Road No.: | LGA No.: | Job No.: |
| Road name: | Suburb: | |
| Latitude: | Longitude: | |
| Plan No.: | Plan rev.: | Rev. date: |
Inventory#
| Item | Value |
|---|
| Circuit / cable protection type: | ❑ HRC Fuse ❑ MCB B ❑ MCB C ❑ Contractor |
| Size (A): | ❑ 10 ❑ 16 ❑ 20 ❑ 25 ❑ 32 |
| Cable protection configuration (phase): | ❑ Single phase ❑ 2 phase ❑ 3 phase |
| Cable type: | ❑ V75 ❑ V90 ❑ XLPE |
| Cable configuration: | ❑ SDI ❑ Multicore ❑ Circular ❑ Flat |
| No. of cores: | ❑ 2 ❑ 3 ❑ 4 ❑ 5 |
| Active conductor size (mm²): | ❑ 4 ❑ 6 ❑ 10 ❑ 16 ❑ 25 ❑ 35 |
| Earth size (mm²): | ❑ 4 ❑ 6 ❑ 10 ❑ 16 ❑ 25 ❑ 35 |
| Pole guard type: | ❑ None ❑ Steel ❑ Timber ❑ Steel earthed ❑ Plastic |
Rate 3 – Road lighting#
Inventory on circuits and cables#
Current status with respect to the last audit / inspection:#
- Last audit / inspection outcomes not yet reviewed to determine remedial works
- No work required from last audit / inspection
- Decommissioned
- Design phase
- Tender phase
- Construction phase
- Remedial works certified and completed
Inspector name:#
Inspector signature:#
Inspection date:#
Rate 3 – Road lighting#
Inventory on poles#
| Field | Value |
|---|
| Region: | |
| Switchboard ID: | |
| Description: | |
| Circuit ID: | |
| Description: | |
| Pole ID: | |
| Description: | |
| Pole number (Energex / Ergon): | |
| Road No.: | LGA No.: | Job No.: |
| Road name: | Suburb: | |
| Latitude: | Longitude: | |
| Plan No.: | Plan rev.: | Rev. date: |
Inventory#
| Item | Value |
|---|
| Is this a joint use pole? | ❑ Yes ❑ No |
| Pole type: | ❑ Slip ❑ Fixed ❑ Hex ❑ Round ❑ Mast arm combination |
| Pole height (m): | ❑ 7.5 ❑ 8.5 ❑ 10 ❑ 12 ❑ 13 ❑ 15 |
| Outreach type | ❑ N/A ❑ Single ❑ Double ❑ Triple ❑ Quad |
| Outreach size (m) | ❑ N/A ❑ 1.0 ❑ 1.5 ❑ 3 |
| Outreach orientation to road (): | |
| Outreach upcast angle (): | ❑ N/A ❑ 0 ❑ 5 ❑ 10 |
| Rate 3 label: | ❑ Yes ❑ No |
| Foot diameter (mm): | |
| Cable size from terminal panel to luminaire (mm²): | ❑ N/A ❑ 1.5 ❑ 2.5 ❑ 4 ❑ 6 ❑ 10 ❑ 12 ❑ 16 ❑ 25 |
| Cable size from pit to terminal panel (mm²): | ❑ N/A ❑ 1.5 ❑ 2.5 ❑ 4 ❑ 6 ❑ 10 ❑ 12 ❑ 16 ❑ 25 |
Rate 3 – Road lighting#
Inventory on poles#
Current status with respect to the last audit / inspection:#
- Last audit / inspection outcomes not yet reviewed to determine remedial works
- No work required from last audit / inspection
- Decommissioned
- Design phase
- Tender phase
- Construction phase
- Remedial works certified and completed
Inspector name:#
Inspector signature:#
Inspection date:#
Rate 3 – Road lighting#
Inventory on luminaires#
| Field | Value |
|---|
| Region: | |
| Switchboard ID: | |
| Description: | |
| Circuit ID: | |
| Description: | |
| Pole ID: | |
| Description: | |
| Luminaire ID: | |
| Description: | |
| Pole number (Energex / Ergon): | |
| Road No.: | LGA No.: | Job No.: |
| Road name: | Suburb: |
| Latitude: | Longitude: | |
| Plan No.: | Plan rev.: | Rev. date: |
Inventory#
| Item | Value |
|---|
| Outreach arm extension size (mm): | ❑ N/A ❑ 1.0 ❑ 1.5 ❑ 2 |
| Luminaire brand: | ❑ Rexel ❑ Sylvania ❑ GEC ❑ Gough ❑ Crouse H ❑ Osram |
| Luminaire type: | ❑ SCO ❑ CO ❑ HM ❑ FL |
| Lamp type: | ❑ SON T ❑ SON E ❑ MH ❑ MV ❑ FL |
| Lamp wattage: | ❑ 70 ❑ 100 ❑ 150 ❑ 250 ❑ 400 |
| Power factor correction: | ❑ Yes ❑ No |
| Photocell: | ❑ Yes ❑ No ❑ Shorted |
Rate 3 – Road lighting#
Inventory on luminaires#
Current status with respect to the last audit / inspection:#
- Last audit / inspection outcomes not yet reviewed to determine remedial works
- No work required from last audit / inspection
- Decommissioned
- Design phase
- Tender phase
- Construction phase
- Remedial works certified and completed
Inspector name:#
Inspector signature:#
Inspection date:#
Rate 3 – Road lighting#
Inventory on pits and conduits#
| Field | Value |
|---|
| Region: | | |
| Switchboard ID: | | |
| Description: | | |
| Pit ID: | | |
| Description: | | |
| Pit connected to: | ❑ Switchboard | ❑ Road lighting pole | ❑ Other |
| Pole ID: | | |
| Description: | | |
| Pole number (Energex/Ergon): | | |
| Road No.: | | LGA No.: | Job No.: |
| Road name: | | Suburb: | |
| Latitude: | | Longitude: | |
| Plan No.: | | Plan rev.: | Rev. date: |
Inventory#
| Item | Value |
|---|
| Pit type: | ❑ No 4 ❑ No 7 ❑ Round |
| Pit material: | ❑ Plastic ❑ Fibro ❑ Concrete ❑ Fibreglass |
| Asbestos in pit material: | ❑ Yes ❑ No ❑ Possible |
| Asbestos in conduit material: | ❑ Yes ❑ No ❑ Possible |
| Asbestos contamination in pit: | ❑ Yes ❑ No ❑ Not tested |
| Pit lid material: | ❑ ❑ Steel ❑ Plastic Concrete |
| Conduit type: | ❑ HD ❑ MD ❑ Corrugated |
| Number of conduits: | | Size (mm): | ❑ 40 ❑ 80 ❑ 50 ❑ 100 |
| Conduit colour: | ❑ Orange ❑ White ❑ Grey |
| Joint type: | ❑ None ❑ Reopenable ❑ 90B1 ❑ Heatshrink |
| Cables in pit: | ❑ Lighting Signal ❑ Detector ❑ Other ITS |
| Slack cable in pit (m): | |
| Fuse size in cable joint kit: | ❑ N/A ❑ 10A ❑ 16A ❑ 20A ❑ 25A ❑ 32A |
Rate 3 – Road lighting#
Inventory on pits and conduits#
Current status with respect to the last audit / inspection:
- Last audit / inspection outcomes not yet reviewed to determine remedial works
- No work required from last audit / inspection
- Decommissioned
- Design phase
- Tender phase
- Construction phase
- Remedial works certified and completed
Additional comments:
Inspector name:
Inspector signature:
Inspection date: