Step 7#

Refer to Standard Drawings listed in Appendix C for details of fabrication and erection.

Figure B.1 – Geographic region
Figure B.1 – Geographic regionp. 33
Table B.1 – Stiffener type and number of supports
OptionPanel stiffener typeNo. of supportsMaximum sign widthRegion ARegion BRegion C
Option 1 – Minimum no. of supports; standard support spacing¹Type 12Maximum sign width3.5m3.0m2.5m
Option 1 – Minimum no. of supports; standard support spacing¹Type 2a2Maximum sign width5.5m5.0m4.5m
Option 1 – Minimum no. of supports; standard support spacing¹Type 2a3Maximum sign width7.3m6.7m6.0m
Option 2 – Additional support; standard support spacingType 13Maximum sign width² (standing support spacing¹)4.7m4.0m3.3m
Option 2 – Additional support; standard support spacingType 2a4Maximum sign width² (standing support spacing¹)8.0m8.0m8.0m
Option 2 – Additional support; standard support spacingType 14Maximum sign width² (standing support spacing¹)6.3m5.4m4.4m
Option 3 – Minimum 10% sign overhangType 12Maximum sign width (10% sign overhang)2.0m1.7m1.5m
Option 3 – Minimum 10% sign overhangType 22Maximum sign width (10% sign overhang)3.3m2.8m2.5m

¹Support spacing may be reduced for signs of width less than tabulated limits provided maximum stiffener overhang specified in Table B.2 following are not exceeded.

² Sign width limited to 8.0m maximum.

Table B.2 – Maximum stiffener overhang
Panel stiffener typeMaximum stiffener overhangRegion ARegion BRegion C
Type 1Maximum stiffener overhang0.7m0.6m0.5m
Type 2Maximum stiffener overhang1.1m1.0m0.9m
Table B.3 – Number of panel stiffeners
Sign height, B (m)No. of stiffeners (Max. stiffener spacing 500m Max. sign panel overhang 150mm)
0.752
1.23
1.84
2.255
2.76
3.37
3.758
3.99
Source: TRUM Vol 3 Part 5 · pages 33–35 Open PDF at this page Search this document